A bonded fixing system attaches cladding panels to the supporting rails without visible screw or rivet heads. Selection depends on the material, expected loads, surface preparation and installation conditions.

Ventilējamās fasādes līmēto plākšņu mezgls ar alumīnija profiliem, līmi un divpusējo līmlenti

What the adhesive fixing detail shows

The drawing shows vertical aluminium rails fixed to brackets, with adhesive and installation tape between the panel and the rail. A ventilated cavity remains behind the cladding. The panels are bonded to the rails.

Surface preparation products, tape and adhesive have different roles. Select the cleaner, activator or primer for the actual panel and rail surfaces in accordance with the system instructions. Test adhesion with samples of the project materials if specified.

What the adhesive and fixing tape do

Double-sided fixing tape initially holds the panel while the adhesive cures and helps maintain the bond-line thickness. The tape alone does not provide the permanent fixing.

Confirm suitability for a ventilated façade, the specific panel material and its rear coating. Use a system intended for this purpose and follow its product and project requirements.

How to organise bonded installation

Align and secure the subframe before bonding. Prepare the bonding faces using the cleaning and priming procedure approved for that combination of materials. Protect the prepared surfaces against contamination.

Apply the tape and adhesive bead at the specified locations. Position and press the panel within the time and using the method specified. Complete panel cutting and adjustments before applying adhesive.

Why control installation conditions?

Surface cleanliness, moisture, temperature and the risk of condensation affect the bond. Use the current documentation for the actual product to determine working times and acceptable conditions.

Before installation begins, decide who will record product batches, storage, surface preparation and conditions. This allows verification after the bond is hidden behind the cladding.

When to consider bonded fixing

Consider this system when the design calls for a smooth face without exposed fasteners. A quote needs the panel type and sizes, the planned subframe and evidence of bonding-system compatibility. Plan for panel replacement and variable weather at the design stage.